Product Details:
Model Name/Number | A1000 |
Brand | Yaskawa |
Motor Types | Induction Motor, Permanent Magnet Motor (SPM) |
Allowable Voltage Fluctuation | -15% to 10% |
Altitude | Up to 1000 meters (dating required at altitudes from 1000 m to 3000 m) |
Humidity | 95% RH or less (no condensation) |
Surrounding Area | Pollution degree 2 or less |
Rated Output Voltage (dependent on input) | Three Ph 200V Class : 200 to 240VAC/Three Ph 400V Class : 380 to 480VAC |
Braking Transistor | Built-in upto 30kW HD rating |
Accel/Decel time | 0.0 to 6000.0 seconds |
Ambient Temperature | -10DegC to +50DegC ( No Deration required), Upto 60 DegC with deration factor |
Torque Limit | All vector control modes allow separate settings in four quadrants |
Frequency Range | 0.01 to 400Hz |
Frequency Accuracy | Digital reference: within +-0.01% of the max. output frequency (-10DegC to +40DegC) |
Frequency Setting Resolution | Digital reference: 0.01 Hz, Analog reference: 0.03 Hz / 60 Hz (11 bit) |
Output Frequency Resolution | 0.001 Hz |
Country of Origin | Made in India |
The A1000 is the premium inverter from YASKAWA.It provides great operation reliability, environmental benefits and energy savings as well as many other user oriented
Product Details:
Model Name/Number | V1000 |
Brand | Yaskawa |
Rated Output Voltage (dependent on input) | Three Ph 200V Class : 200 to 240VAC/Three Ph 400V Class : 380 to 480VAC/Single Ph 200V |
Speed Control Range | 1:100 (Open Loop Vector Control), 1:20 to 40 (V/f Control), 1:10 (PM Open Loop Vector Control) |
Altitude | Up to 1000 meters |
Allowable Voltage Fluctuation | -15% to 10% |
Motor Types | Induction Motor, Permanent Magnet Motor (IPM/SPM) |
Starting Torque | 200% / 0.5 Hz (assumes Heavy Duty rating IM of 3.7 kW or less using Open Loop Vector Control) |
Frequency Range | 0 to 400Hz |
Output Frequency Resolution | 20 bit of maximum output frequency (parameter E1-04 setting) |
Shock | 10 to less than 20 Hz (9.8 m/s2) max., 20 to 55 Hz (5.9 m/s2) max. |
Control Methods | Open Loop Vector Control (Current Vector), V/f Control, PM Open Loop Vector Control (for SPM and IPM |
Torque Limit | Open Loop Vector Control allows separate settings in four quadrants |
Ambient Temperature | -10 to +50DegC (open chassis), -10 to +40DegC (enclosure) |
Humidity | 95 RH% or less (no condensation) |
Country of Origin | Made in India |
Product Details:
Model Name/Number | U1000 |
Brand | Yaskawa |
Surrounding Area | Pollution degree 2 or less |
Allowable Frequency Fluctuation | +-3% |
Shock | 10 to 20 Hz: 9.8 m/s2 (CIMR-UD4 0477 to 4 0930: 5.9 m/s2) |
Carrier Frequency | 4 kHz (User adjustable up to 10 kHz. Derating may be required.) |
Allowable Voltage Fluctuation | -15% to 10% |
Humidity | 95% RH or less (no condensation) |
Altitude | Up to 1000 meters |
Ambient Temperature | -10DegC to +50DegC |
Accel/Decel time | 0.0 to 6000.0 seconds |
Multi Funcction Digital Inputs | 8 Digital Inputs ( NPN or PNP ) |
Programming Interface | Serial port or USB B port in front of VFD |
Rated Output Voltage (dependent on input) | Three Ph 200V Class : 200 to 240VAC/Three Ph 400V Class : 380 to 480VAC |
Multi Function Analog Output | 2 Multi function Analog outputs FM-AC & AM-AC (-10 to +10 Vdc (2 mA)) |
Output Frequency Resolution | 0.001 Hz |
Frequency Range | 0.01 to 400Hz |
Applications For Energy Savings:
Product Details:
Brand | Yaskawa |
Model Name/Number | R1000 |
Ambient Temperature | -10 to +40DegC (UL Type1), -10 to +50DegC (IP00, IP20) |
Control Method | 120Deg excitation method |
Programming Interface | Serial port or USB B port in front of VFD |
Allowable Voltage Fluctuation | -15% to 10% |
Input Power Factor | 0.9 min. (for rated load) |
Humidity | 95% RH or less (no condensation) |
Allowable Frequency Fluctuation | +-2% |
Optional communication Protocols | Mechatrolink, CC-Link |
Compatible Inverter Types | A1000, V1000, J1000, GA700, GA500, G7, L1000A, Servo Drives & All conventional Inverters (with a DC |
Serial communication | MEMOBUS/Modbus (RTU mode) comm. RS-485, Max. 115.2 kbps |
Regenerative Torque | 150% 30 s, 100% 25% ED 60 s, 80% continuous |
Altitude | Up to 1000 meters (derating required at altitudes from 1000 to 3000 m) |
Area of Use | Indoors (Protected from corrosive gases and dust) |
The R1000 is a power regenerative unit with both braking and regenerative functions. The R1000 shows great energy-saving performance in combination with an inverter. The R1000 will dramatically affect applications with large regenerative loads such as cranes and elevators.Because the R1000 does not require a braking resistor unit, it requires less space and enhances braking ability.
Product Details:
Model Name/Number | D1000 |
Brand | Yaskawa |
Rated Output Voltage (dependent on input) | Three Ph 200V Class : 330 Vdc/Three Ph 400V Class : 660 Vdc |
Compatibe Inverter Types | A1000, V1000, J1000, GA700, GA500, G7, L1000A, Servo Drives & All conventional Inverters (with a DC |
Control Methods | Sine wave PWM |
Ambient Temperature | -10 to +50DegC (IP00/IP20/Open Type enclosure) |
Allowable Voltage Fluctuation | -15% to 10% |
Allowable Frequency Fluctuation | +-2% |
Optional communication Protocols | Mechatrolink, Profibus, CC-Link, Devicenet |
Humidity | 95% RH or less (no condensation) |
Multi Function Digital Inputs | 8 Digital Inputs ( NPN or PNP ) . |
Altitude | Up to 1000 meters (derating required at altitudes from 1000 m to 3000 m) |
Country of Origin | Made in India |
The D1000 regenerative converter unit from YASKAWA saves energy and space. Suitable for both regenerative individual drives and systems of inverter drives, servo axes or robots, the D1000 feeds excess braking energy back into the grid instead of converting it into heat . This not only reduces energy consumption and cost but also contributes to the protection of our environment.
Features:
Product Details:
Material | ABS Plastic |
Usage/Application | Industrial |
Phase | Three Phase |
Model Name/Number | D1000 |
Brand | Yaskawa |
Peak Torque | 50 nm |
Rated Speed | 200-300 rpm |
Product Details:
Minimum Order Quantity | 5 Piece |
Motor power | 500 HP |
Usage | For Industrial Machinery |
Model Name/Number | Varispeed G7 |
Brand | Yaskawa |
Phase | 3 Phase |
Product Details:
Brand | Yaskawa |
Momentary Overcurrent Protection | Drive stops when output current exceeds 200% of the HD output current. |
Under voltage Protection | 200 V class: Stops when the DC bus voltage decreases to less than approximately 190 V |
Allowable Frequency Fluctuation | +-5% |
DC Supply | DC 24 V Power supply, Output 24 V, max. 150 mA |
Output Frequency Resolution | 0.001 Hz |
Accel/Decel time | 0.0 to 6000.0 seconds |
Shock | 10 Hz to 20 Hz, 1 G (9.8 m/s2)/20 Hz to 55 Hz, 0.6 G (5.9 m/s2) |
Frequency Setting Resolution | Digital reference: 0.01 Hz Analog reference: 1/2048 of the maximum output frequency setting (11 bit) |
Torque Limit | Parameter settings allow separate limits in four quadrants in Open Loop Vector Control, Advanced Ope |
Overvoltage Protection | 200 V class: Stops when the DC bus voltage is more than approximately 410 V |
Allowable Voltage Fluctuation | -15% to 10% |
Frequency Accuracy | Digital reference: within +-0.01% of the max. output frequency (-10dC to +40DC) Analog reference: wit |
Ambient Temperature | -10 Deg C to +50Deg C ( No Deration required), Upto 60 Deg C with deration factor |
Motor Protection | Motor overheat protection based on output current |
Pulse Train | 1 Pusle Train output (0- 32 kHz (2 kq)) |
Country of Origin | Made in India |
Product Details:
Model Name/Number | GA500 |
Brand | Yaskawa |
Motor Protection | Motor overheat protection based on output current |
DC Supply | DC 24 V Power supply, Output 24 V, max. 150 mA |
Braking Transistor | Built-in for all ratings (20% braking torque) |
Frequency Accuracy | Digital reference: within +-0.01% of the max. output frequency (-10 DegreeC to +40 DegreeC) |
Frequency Setting Resolution | Digital reference: 0.01 Hz |
Torque Limit | Parameter settings allow separate limits in four quadrants in Open Loop Vector Control, Advanced Ope |
Rated Output Voltage (dependent on input) | Single Ph 200V Class : 200 to 240VAC/Three Ph 200V Class : 200 to 240VAC/Three Ph 400V Class : 380V |
Altitude | 1000 m or less with no deration . Altitudes over 1000 m and up to 4000 m are possible |
Humidity | 95% RH or less (no condensation) |
Surrounding Area | Pollution degree 2 or less |
Allowable Frequency Fluctuation | +-5% |
Frequency Range | 0 to 590Hz |
Output Frequency Resolution | 0.001 Hz |
Accel/Decel time | 0.0 to 6000.0 seconds |
Ambient Temperature | -10deg C to +50DegC ( No Deration required), Upto 60 Deg C with deration factor |
Shock | 10 Hz to 20 Hz, 1 G (9.8 m/s2)/20 Hz to 55 Hz, 0.6 G (5.9 m/s2) |
Allowable Voltage Fluctuation | -15% to 10% |
Product Details:
Brand | Yaskawa |
Model Name/Number | J1000 |
Rated Output Voltage (dependent on input) | Three Ph 200V Class : 200 to 240VAC/Three Ph 400V Class : 380 to 480VAC/Single Ph 200V |
Control Methods | V/f Control (V/f) |
Starting Torque | 150% @3Hz for V/f |
Shock | 10 to less than 20 Hz (9.8 m/s2) max., 20 to 55 Hz (5.9 m/s2) max. |
Allowable Frequency Fluctuation | +-5% |
Multi Function Digital Inputs | 5 Digital Inputs ( NPN or PNP ) , 24VDC. |
Speed Control Range | 1:20 to 1:40 |
Frequency Setting Resolution | Digital reference: 0.01 Hz |
Allowable Voltage Fluctuation | -15% to 10% |
Altitude | Up to 1000 meters |
Multi Function Digital Outputs | 1 Programmable Relay with MA-MB-MC (250 Vac, 10 mA to 1 A;30 Vdc, 10 mA to 1 A) |
Multi Function Analog Output | 1 Multi function Analog output AM-AC (0 - 10 V, 2 mA) |
Frequency Range | 0 to 400Hz |
Output Frequency Resolution | 20 bit resolution at maximum output frequency |
Ambient Temperature | -10 to +50DegC (open chassis), -10 to +40DegC (enclosure) |
Humidity | 95 RH% or less (no condensation) |
Country of Origin | Made in India |
The J1000 meets all automation requirements for compact applications with variable speed operation and energy saving characteristics. A wide range of useful functions upgrade your machine and offer great potentials
Main Application's:
Product Details:
Brand | Yaskawa |
Model Name/Number | Varispeed G7 |
Speed Control Range | 1:200 (open loop vector control 2), 1:1000 (vector control with PG) |
Charge LED | Charge LED illuminates when DC bus voltage is more than 50 V. |
Multi Function Analog Inputs | 3 Multi function Analog input A1(0 to10 V), A2(4 to 20 mA) & A3(0 to10 V) |
Humidity | 95% RH or less (no condensation) |
Allowable Frequency Fluctuation | +-5% |
Starting Torque | 150% at 0.3 Hz (open loop vector control 2), 150% at 0 min-1 (vector control with PG)* |
Ambient Temperature | -10 to 45 Deg. C(Open chassis type) |
Multi Function Analog Output | 2 Multi function Analog outputs FM-AC & AM-AC (-10 to 10 V 2 mA) |
Torque Limit | Can be set by parameter: 4 steps available (only when vector control) |
Altitude | 1000 m max. |
Momentary Overcurrent Protection | Drive stops when output current exceeds 200% of the rated output current. |
Rated Output Voltage (dependent on input) | Three Ph 200V Class : 200 to 240VAC Three Ph 400V Class : 380 to 480VAC |
Overload Protection | 150% rated output current for 1 minute, 200% rated output current for 0.5 s |
Motor Protection | Protection by electronic thermal overload relay. |
Ground Fault Protection | Protection by electronic circuit |
Allowable Voltage Fluctuation | -15% to 10% |
Frequency Setting Resolution | Digital reference: 0.01 Hz; Analog reference: 0.03 Hz/60 Hz (11-bit + sign) |
Output Frequency Resolution | 0.001 Hz |
Multi Funcction Digital Inputs | 12 Digital Inputs ( NPN or PNP ) . |
Stall Prevention | Stall prevention during acceleration/deceleration and constant speed operation |
Frequency Range | 0.01 Hz to 400 Hz |
Braking Transistor | Built-in braking transistor provided for AC Drives of 15 kW or less (200/400 V) |
Frequency Accuracy | Digital reference: +/-0.01%, -10 to 40 Deg. C, Analog reference: +/-0.1%, 25 +/-10 Deg. C |
Heatsink Overheat Protection | Thermistor |
Carrier Frequency | Derating the output current enables a maximum of 15 kHz to be set.( Based on rating ) |
Accel/Decel time | 0.01 to 6000.0 s (4 selectable combinations of independent acceleration and deceleration settings) |
Area of Use | Indoor (Protected from corrosive gasses and dust) |
Product Details:
Brand | Yaskawa |
Overload Protection | Drive stops after 60 s at 150% of rated output current |
Network Communications | Modbus communications. (RS-422/485 max. 115.2 kbps) standard. Options: CANopen, others |
Frequency Setting Resolution | Digital reference: 0.01 Hz, Analog reference: 0.03/60 Hz (11 bit) |
Torque Accuracy | +/- 5% |
S-Curve (Jerk) Setting | Starting, acceleration end, deceleration start, leveling, stop setting independently |
Motor Protection | Electronic thermal motor overload protection |
Starting Torque | 200% at 0.3 Hz (Open Loop Vector Control), 200% at 0 rpm (Closed Loop Vector Control, PM Closed Loop |
Overload Accuracy | 150% of rated output current for 60 s |
Frequency Setting Signal | -10 to +10V, 0 to +10V |
Heatsink Overheat Protection | Protection by thermistor |
Area of Use | Indoors |
Feedback Devices | Incremental, EnDat, SIN/COS, HIPERFACE |
Control Method | Sine wave PWM (Closed Loop Vector Control, Open Loop Vector Control, V/f Control, PM FIux Vector con |
Frequency Control Range | 0.01 to 200 Hz |
V/f Characteristics | User programmable |
Momentary Overcurrent Protection | Drive stops when output current exceeds 200% |
Braking Resistance Overheat Protection | Overheat sensor for braking resistor |
Storage Temperature | -20 to 60 DegreeC (short-term temperature during transportation) |
Output Speed Resolution | 0.001 Hz |
Ground Fault Protection | Protection by electronic circuit |
Ambient Temperature | -10 to 40 DegreeC (IP00 enclosure with top protective cover); -10 to 50 DegreeC (IP00 enclosure) |
Humidity | 95% RH or less (non-condensing) |
Torque Limit | Vector control allows separate settings in four quadrants |
Altitude | Up to 1000 meters without derating, up to 3000 meters with derating |
Frequency Accuracy (Temperature Fluctuation) | Digital reference: +-0.01%, -10 to +40 DegreeC, Analog reference: +-0.1%, 25 DegreeC +-10 DegreeC |
Protection Design | IP00 with top protective cover, IP00 |
Product Details:
Brand | Yaskawa |
Model Name/Number | GA700 |
Input Voltage | 0.75~5 kw |
Input Phase | 1 - Phase |
Output | Digital |
Country of Origin | Made in India |
Product Details:
Minimum Order Quantity | 1 Piece |
Model Name/Number | V1000 |
Brand | YASKAWA |
Motor Power | 0.4 kW to 400 kW |
Input Voltage | 3 Phase 415 V 50 Hz AC |
Input Phase | 3 - Phase |
Input Frequency | 50 Hz |
Output Current | 2 Amps to 200 Amps |
Start Up Torque | 250 % |
Control Procedure | Vector control |
Country of Origin | Made in India |
Additional Information:
Product Details:
Minimum Order Quantity | 5 Unit |
Model Name/Number | A1000 |
Brand | YASKAWA |
Motor Power | 1 HP TO 1000 HP |
Input Voltage | 400 Volts 3 Phase AC 50 Hz |
Input Phase | 3 - Phase |
APPLICATION | PUMPS, FANS, CONVEYORS, PROCESS INDUTRIES, EXTRUDERS, MIXER CRANE,ELEVATORE ETC.. |
POWER. | 1 HP to 1000 HP |
Product Details:
Model Name/Number | J1000 |
Brand | Yaskawa |
Multi Funcction Digital Inputs | 5 Digital Inputs ( NPN or PNP ) , 24VDC. |
Shock | 10 to less than 20 Hz (9.8 m/s2) max., 20 to 55 Hz (5.9 m/s2) max. |
Type | Versatile Compact V/f Control Drive |
Optional communication Protocols | RS232C, RS422/485 |
Momentary Power Loss Ride-Thru | Stops when power loss is longer than 15 ms. |
Starting Torque | 150% @3Hz for V/f |
Humidity | 95 RH% or less (no condensation) |
Frequency Setting Resolution | Digital reference: 0.01 Hz Analog reference: 1/1000 of the maximum frequency |
Motor Types | Induction Motor |
Stall Prevention | Separate settings allowed during acceleration and during run. Enable/disable only during deceleratio |
Overload Protection | Drive stops after 60 s at 150% of rated output current (Heavy Duty Rating) |
Momentary Overcurrent Protection | Drive stops when output current exceeds 200% of Heavy Duty Rating |
Area of Use | Indoors |
Allowable Frequency Fluctuation | +-5% |
Altitude | Up to 1000 meters |
Ambient Temperature | -10 to +50 Deg. C (open chassis), -10 to +40 Deg. C (enclosure) |
Output Frequency Resolution | 20 bit resolution at maximum output frequency |
Multi Function Digital Outputs | 1 Programmable Relay with MA-MB-MC (250 Vac, 10 mA to 1 A;30 Vdc, 10 mA to 1 A) |
Allowable Voltage Fluctuation | -15% to 10% |
Ground Fault Protection | Protection by electronic circuit |
Heatsink Overheat Protection | Thermistor |
Multi Function Analog Output | 1 Multi function Analog output AM-AC (0 - 10 V, 2 mA) |
Motor Protection | Motor overheat protection based on output current |
Speed Control Range | 1:20 to 1:40 |
Control Methods | V/f Control (V/f) |
Charge LED | Charge LED illuminates when DC bus voltage is less than 50 V. |
Accel/Decel time | 0.0 to 6000.0 s (2 selectable combinations of independent acceleration and deceleration settings) |
Frequency Range | 0 to 400Hz |
Product Details:
Model Name/Number | L1000A |
Brand | Yaskawa |
Accel/Decel time | 0.0 to 6000.0 seconds |
Stall Prevention | Stall prevention during acceleration |
Humidity | 95% RH or less (no condensation) |
Allowable Voltage Fluctuation | -15% to 10% |
Rated Output Voltage (dependent on input) | Three Ph 200V Class : 200 to 240VAC/Three Ph 400V Class : 380 to 480VAC |
Speed Control Range | 1:40 (V/f Control) 1:1500 (Closed Loop Vector Control) |
Frequency Range | 0.01 to 200 Hz |
Ambient Temperature | -10 to 40DegC (open-chassis), -10 to 50Deg C (NEMA Type 1) |
Altitude | Up to 1000 meters |
Shock | 10 Hz to 20 Hz, 9.8 m/s2 max. 20 Hz to 55 Hz, 5.9 m/s2 max. |
Allowable Frequency Fluctuation | +-5% |
Serial communication | MEMOBUS/Modbus (RTU mode) comm. RS-485, Max. 115.2 kbps |
Motor Types | Induction Motor, Permanent Magnet Motor (SPM/IPM) |
Torque Limit | All vector control modes allow separate settings in four quadrants |
Output Frequency Resolution | 0.001 Hz |
L1000A is the new special purpose lift inverter drive designed for 3 Million starts at 165% output current It provides advanced control functions to run induction and PM motor applications in geared or gearless elevator systems
Features:
Product Details:
Model Name/Number | A1000 |
Brand | Yaskawa |
Frequency Setting Resolution | Digital Reference Input: 0.01 Hz |
Frequency Reference Setting Signal | -10 to +10 Volts, 0 to +10 Volts, 4 to 20 mAmps, pulse train |
Speed Control Accuracy | Open Loop Vector: +/- 0.2% (25 degrees C +/- 10 degrees C) Closed Loop Vector: +/- 0.02% (25 degrees |
Speed Response | Open Loop Vector: 10 Hz (25 degrees C +/- 10 degrees C) Closed Loop Vector: 50 Hz (25 degrees C +/- |
Torque Limit | Separate limit settings in four quadrants for OLC, CLV, Advanced CLV |
Motor Protection | Motor overheat protection based on output current |
Control Method | V/F Control, V/F Control with PG Open Loop Vector Control |
Frequency Control Range | 0.01 Hz to 150 Hz |
Output Frequency Resolution | 0.001 Hz |
Accel / Decel Time | 0.00 to 6000.0 seconds (4 selectable combinations of independent accel and decel settings) |
Braking Torque | Based on external braking or regenerative system |
The drive is of modular design with separate converter and inverter sections installed in a common enclosure. These sections can be paralleled to increase capacity to 2250 amps at 400 and 690 volts.
Product Details:
Model Name/Number | U1000 |
Brand | YASKAWA |
Motor Power | 0.75KW - 630KW |
Input Voltage | 230V - 415V |
Input Phase | 3 - Phase |
Product Details:
Model Name/Number | V1000 |
Brand | YASKAWA |
Motor Power | 0.75KW - 18.5KW |
Input Voltage | 230V - 415V |
Input Phase | 3 - Phase |
Product Details:
Model Name/Number | J1000 |
Brand | YASKAWA |
Motor Power | 0.1KW - 5.5KW |
Input Voltage | 230V - 415V |
Input Phase | 3 - Phase |
Product Details:
Type | AC |
Speed | 3000 rpm |
Power | 400 watts - 55KW |
Voltage | 230V 3phase AC - 415V 3phase AC |
Single Phase Servo Pack Model | SDGV |
Three Phase Servo Pack Model | SDGM |
Brand | YASKAWA |
Product Details:
Brand | Yaskawa |
Torque | 7.00 Nm |
Input Voltage | 220 V |
Input Phase | 3 - Phase |
Model Name/Number | Sigma 7 |
Rated Power | 220 KW |